8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 513

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

513

8

Basic drive functions (MCK)

8.3

MCKInterface

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Inputs

Identifier

Data type

Information/possible settings

wInMckPosCtrl_1

wInMckPosCtrl_2

WORD

Direct specification of the MCK control word 1 & 2

• For example, via a master control unit that is also connected to the fieldbus. For

this purpose, the control word inputs can be directly connected to the LP_MciIn

respectively LP_CanIn1 fieldbus interface.

• The two control words together form a 32-bit double control word with which

the entire Motion Control Kernel is controlled.

• All motion profiles in the different operating modes can be operated via this

interface.

• See the "

MCK control word

" chapter for a detailed description of the individual

control bits.

wOperationMode

WORD

Selection of the operating mode of the Motion Control Kernel

• Only bit 0 ... bit 3 of wOperationMode are evaluated.

• If an invalid operating mode is selected, the response set in

C00595/11

is

activated (Lenze setting: "Warning").

• The current operating mode is displayed in

C01243

.

0

Speed follower

1

Homing

2

Manual jog

3

Positioning

4

Stop

5

Position follower

6 ... 15 Reserved for future extensions

bOperationMode_1

...

bOperationMode_8

BOOL

Binary-coded selection of the operating mode of the Motion Control Kernel

• See the "

MCK control word

" chapter for a detailed description of the individual

control bits.

• If an invalid operating mode is selected, the response set in

C00595/11

is

activated (Lenze setting: "Warning").

• The current operating mode is displayed in

C01243

.

bManJogPos

bManJogNeg

BOOL

Manual jog

:

bManJogPos = TRUE: Manual jog right

bManJogNeg = TRUE: Manual jog left

Both inputs = TRUE: No change compared to previous state

Both inputs = FALSE: Stop manual jog

bManJogExecute2ndVel

BOOL

Manual jog

: Changeover to speed 2

FALSE Speed 1 (

C01231/1

) active

TRUE Speed 2 (

C01231/2

) active

bReleaseLimitSwitch

BOOL

Manual jog

: Retract operated limit switch

TRUE Retract operated limit switch (in opposite direction)

Advertising