17.2.27

LS_ParFreeUnit_2

This system block outputs 16 parameterisable position signals.

• In contrast to the SB

LS_ParFree_p

, the positions are set in the application unit [unit] instead of

in [increments].

• The bDataValid status signal indicates that the internal position conversion is completed and

the output data are consistent.

Outputs

Parameter

Identifier

Data type

Value/meaning

bDataValid

BOOL

Status signal "Position conversion completed, data consistent"

TRUE The conversion of the positions from [unit] to [increments] is

completed.

dnC475_17 ... dnC475_32

DINT

Output of the position signals parameterised in

C00475/17...32

in [increments]

• Observe bDataValid status signal!

Parameter

Possible settings

Info

C00475/17...32

-214748.3647

unit

214748.3647 Setting of the position signals to be

output

GQ&B

GQ&B

GQ&B

GQ&B

GQ&B

&

&

&

&

&