17 function library – Lenze 8400 HighLine User Manual

Page 1436

Advertising
background image

17

Function library

17.1

Function blocks

1436

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

dnPosOut_1_p

...

dnPosOut_8_p

DINT

Detected positions

dnDeltaPos_12_p

dnDeltaPos_23_p

dnDeltaPos_34_p

...

dnDeltaPos_18_p

DINT

Calculated distances between the detected positions

dnDeltaPos_12_p = Distance between dnPosOut_1_p and dnPosOut_1_p

dnDeltaPos_23_p = Distance between dnPosOut_2_p and dnPosOut_3_p

dnDeltaPos_34_p = Distance between dnPosOut_3_p and dnPosOut_4_p

...

dnDeltaPos_18_p = Distance between dnPosOut_1_p and dnPosOut_8_p

wLastMeasure

WORD

Memory location number (1 ... 8) of the last measurement

Parameter

Possible settings

Info

C01020

Memory length

• Lenze setting: 7 measurements

1 1 measurement
2 2 measurements

... ...

7 7 measurements

C01021

Memory type

• Lenze setting: No ring buffer

0 No ring buffer
1 Ring buffer

C01022

Input selection

• Lenze setting: Pos input

0 Pos input
1 V input

C01023

Edge selection

• Lenze setting: HIGH edge

0 High edge
1 Low edge
2 High and low edge