C00463

Parameter | Name:

C00463 | Remote: MCK control

Data type: UNSIGNED_32

Index: 24112

d

= 5E30

h

From version 06.00.00

This parameter serves to control the functions of the Motion Control Kernel for

PC manual control

.

Setting range

(min. hex value | max. hex value)

0x00000000

0xFFFFFFFF

Value is bit-coded:

Bit 0 OpMode_Bit0
Bit 1 OpMode_Bit1
Bit 2 OpMode_Bit2
Bit 3 OpMode_Bit3
Bit 4 ManJogPos
Bit 5 ManJogNeg
Bit 6 ManExecute2ndSpeed
Bit 7 ReleaseLimitSwitch
Bit 8 HomStartStop
Bit 9 HomSetPos

Bit 10 HomResetPos
Bit 11 EnableSpeedOverride
Bit 12 EnableAccOverride
Bit 13 EnableSRampOverride
Bit 14 PosTeachSetPos
Bit 15 PosTeachActPos
Bit 16 PosExecute
Bit 17 PosFinishTarget
Bit 18 PosDisableFollowProfile
Bit 19 PosStop
Bit 20 PosModeBit0
Bit 21 PosModeBit1
Bit 22 PosModeBit2
Bit 23 PosModeBit3
Bit 24 ProfileNo_Bit0
Bit 25 ProfileNo_Bit1
Bit 26 ProfileNo_Bit2
Bit 27 ProfileNo_Bit3
Bit 28 ProfileNo_Bit4
Bit 29 ProfileNo_Bit5
Bit 30 ProfileNo_Bit6
Bit 31 ProfileNo_Bit7

Subcodes

Lenze setting

Info

C00463/1

0x00000000

Remote: MCK control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT