bTorqueLimitAdaptOn

BOOL

Adaptation of torque limitation

TRUE Activate adaptation of torque limitation.

nTorqueLimitAdapt_a

INT

Value for adaptation of torque limitation

• Scaling: 16384 ≡ 100 % of the torque limit specified at the

LS_MotorInterface

system block via the nTorqueMotLimit_a and nTorqueGenLimit_a inputs.

Control words
MCK: wMotionCtrl1

wMotionCtrl2

WORD

MCK control word 1 & 2

• The two control words together form a 32-bit double control word with which

the entire Motion Control Kernel is controlled.

• All motion profiles in the different operating modes can be operated via this

interface.

• See the "

MCK control word

" subchapter for a detailed description of the

individual control bits.

• Display parameter:

C01240

wAuxCtrl

WORD

For future extensions - Input has no function at present time!

Additional control word

wSMCtrl

WORD

Interface to the optional safety system.

• Setting control bit 0 ("SafeStop1") in this control word causes e.g. the automatic

deceleration of the drive to standstill within this application (in the Motion

Control Kernel).

• See the "

Interface to safety system

" subchapter for a detailed description of the

individual control bits.

Control and setpoint signals for Motion Control Kernel function
dnProfilePosition_p

DINT

Profile position in [increments]

• Position which is to be entered into a profile data set selected via the

MCK control

word

.

• In the "absolute" mode, this position is a target position. However, in the

"relative" mode it is a relative traverse path.

Consideration of residual value in case of external profile calculation

nSpeedAddValue_v

INT

Additive speed setpoint in [inc/ms]

nSpeedOverride_a

INT

Value for

Speed override

• Percentage multiplier (0 ... 199.99 %) for the currently active speed.

• 16384 ≡ 100 % of the maximum traversing speed (display in

C01211/1

).

• If the override value is 0 %, the drive is brought to a standstill.

nAccOverride_a

INT

Value for

Acceleration override

• Percentage multiplier (0 ... 199.99 %) for the currently active acceleration.

• 16384 ≡ 100 % of the parameterised acceleration of the corresponding operating

mode.

• If the override value is 0 %, acceleration ceases.

nSRampOverride_a

INT

Value for

S-ramp smoothing override

• Percentage multiplier (0 ... 100 %) for the currently active acceleration.

• 16384 ≡ 100 % of the parameterised S-ramp time (

C01306/1...15

).

• Values > 16384 are ignored.

Note!

If the nSRampOverride_a input remains unconnected or if an override value of "0 %"

is selected, activation of the S-ramp override causes deactivation of the S-ramp time.

• Deactivation of the S-ramp time before the start of a profile with S-ramp time

causes linear ramp generation.

• Deactivation of the S-ramp time during a traversing process, however, is not

accepted immediately in the profile generator, but the profile generator checks

automatically when an online change of the ramp form can be carried out and

then initiates it automatically.