9diagnostics & error management – Lenze 8400 HighLine User Manual

Page 622

Advertising
background image

9

Diagnostics & error management

9.4

Drive diagnostics via keypad/bus system

622

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Display parameters
The parameters listed in the following tables serve to query current states and actual values of the

controller for diagnostic purposes, e.g. by using the keypad, a bus system or the »Engineer« (with an

online connection to the controller).

• These parameters are listed in the »Engineer« parameter list and the keypad in the Diagnostics

category.

• A detailed description of these parameters can be found in the chapter "

Parameter reference

"

( 789)

.

Parameter

Display

C00051

MCTRL: Actual speed value

C00052

Motor voltage

C00053

DC-bus voltage

C00054

Motor current

C00056/1

Torque demand

C00056/2

Actual torque value

C00058

Output frequency

C00061

Heatsink temperature

C00064/1

Device utilisation (Ixt)

C00064/2

Device utilisation (Ixt) 15s

C00064/3

Device utilisation (Ixt) 3 min

C00133

Brake resistor utilisation

C00136/1

MCI control word

C00136/2

CAN control word

C00137

Device status

C00138/1

SYS control signals

C00138/2

MCK control signals

C00138/3

FWM control signals

C00150

Status word

C00158

Cause of controller inhibit

C00159

Cause of quick stop QSP

C00165/1

Status determining error (displayed as a numeric text)

C00165/2

Current error (displayed as a numeric text)

C00168

Status determining error (display of 32-bit number)

C00170

Current error

C00166/1

Error type, status determining

C00166/2

Error subject area, status determining

C00166/3

Error ID, status determining

C00166/4

Error type, current

C00166/5

Error subject area, current

C00166/6

Error ID, current

C00177/1

Switching cycles mains switching

C00177/2

Switching cycles output relay

C00177/3

Stress counter - short circuit

C00177/4

Stress counter - earth fault

C00177/5

Stress meter clamp

Advertising