C01211 | mck: speed, C01213 | mck: max. traversing distance, C01215 | mck: following error – Lenze 8400 HighLine User Manual

Page 1065: Display in, C01211/1, C01244/2, C01215/2, C01213/1, C01215/1, Ror in

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1065

15

Parameter reference

15.2

Parameter list | C01211

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01211

C01213

C01215

Parameter | Name:

C01211 | MCK: Speed

Data type: INTEGER_32

Index: 23364

d

= 5B44

h

Display of the current speed data
Display range

(min. value | unit | max. value)

-214748.3647

units/s

214748.3647

Subcodes

Info

C01211/1

MCK: Max. traversing speed 100%_C11

• Display of the maximum traversing speed based on

the reference speed set in

C00011

.

C01211/2

MCK: Set speed

From version 12.00.00

C01211/3

MCK: Actual speed

From version 12.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01213 | MCK: Max. traversing distance

Data type: INTEGER_32

Index: 23362

d

= 5B42

h

Display of current position limits
Display range

(min. value | unit | max. value)

-2147480000

units

2147480000

Subcodes

Info

C01213/1

MCK: Max. traversing distance

• Display of the maximum distance to be traversed

referred to the 32-bit display area (max. 2147483647

increments).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01215 | MCK: Following error

Data type: INTEGER_32

Index: 23360

d

= 5B40

h

Limits for following error monitoring system

Following error monitoring system

Setting range

(min. value | unit | max. value)

0.0000

units

214748.0000

Subcodes

Lenze setting

Info

C01215/1

0.0000 units

MCK: Following error limit 1

• First limit of the maximum following error for

monitoring and response activation.

C01215/2

0.0000 units

MCK: Following error limit 2

• Second limit of the maximum following error for

monitoring and response activation.

C01215/3

0.0000 units

MCK: Following error SetPos=ActPos

From version 14.00.00

Monitoring of the following error in case of controller

inhibit

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Advertising