5

Motor control (MCTRL)

5.5

V/f characteristic control - energy-saving (VFCplusEco)

176

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5.3

Basic settings

The "Initial commissioning steps" listed in the table below are sufficient for the V/f characteristic

control - energy-saving (VFCplusECo).

• Detailed information on the individual steps can be found in the following subchapters.

Tip!
Information on the optimisation of the control mode and the adaptation to the real

application is provided in chapter "

Optimising the control mode

".

( 177)

Parameterisable additional functions are described correspondingly in the chapter

"

Parameterisable additional functions

".

( 255)

Initial commissioning steps

1. Determine the motor control:

C00006

= "11: VFCplusEco: V/f energy-saving"

2. The required motor data are pre-initialised depending on the device and thus, they do not need to be

entered directly.In order to achieve a high energy optimisation, these motor data can be entered (see the

following section).
Set the motor selection/motor data

• When selecting and parameterising the motor, the motor nameplate data and the equivalent circuit

diagram data are relevant. Detailed information can be found in the "

Motor selection/Motor data

"

chapter.

( 132)

Depending on the motor manufacturer, proceed as follows:
Lenze motor:

Selecting a motor from the motor catalogue in the

»Engineer«

- or -

1.Set the motor nameplate data

2.

Automatic motor data identification

Third party manufacturer's motor:

1.Set the motor nameplate data

2.

Automatic motor data identification

or set known

equivalent circuit diagram manually:

C00084

: Motor stator resistance

C00085

: Motor stator leakage inductance

C00092

: Motor magnetising inductance

3.

Defining current limits (Imax controller)

.

( 159)