17.1.139.2 Example

The current speed at nSet_v and the gearbox factors serve to create a specific machine measuring

system from the motor measuring system.

• 216 increments in the motor measuring system are to correspond to 1 motor revolution.
• 216 increments in the machine measuring system (nOut16) are to correspond to 1 machine

shaft revolution.

Initialise integrator
A FALSE/TRUE edge at bTPReceived initialises the integrator, i.e. a calculation with dnTPPosition_p

and dnLoadVal_p is made:

• After initialisation is completed, the bInitDone output is set to TRUE in the next call cycle.
• In case of a renewed initialisation without a previous reset (bReset = TRUE), the bInitDone

output is set to FALSE for a task cycle.

Reset integrator
When bReset is set to TRUE, the integrator is set to 0. No calculations are made.

• The Boolean outputs are set to FALSE.
• The bReset input has the highest priority.

Load integrator
When bLoad is set to TRUE, the integrator is loaded with the value at dnLoadVal_p and the outputs

are set.

• When bLoad is set to TRUE, the input is not integrated and no check for overflow is executed.
• When bLoad is reset to FALSE, the integrator continues from the loaded value. The bInitDone

output is reset to FALSE after a FALSE/TRUE edge at bTPReceived with a delay of one call cycle.

nOut16

(INT) dnLoadVal_p dnTPPosition_p Gearbox factor

+

(

)

=

dnOut32_p

dnLoadVal_p dnTPPosition_p Gearbox factor

+

=