Basic drive functions (MCK)

8.6

Homing

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 8: >_TP

Procedure:

1. Movement in positive direction with start profile data set.
2. Following edge of the touch probe sensor sets home position.

Mode 9: <_TP

Procedure:

1. Movement in negative direction with start profile data set.
2. Following edge of the touch probe sensor sets home position.

Touch probe

Mode 8

>

TP

Offset path

Sequence profile (optional)

Start speed

Profile speed

Lp

Active

Active

Active

Active

Ln

Inactive

Inactive

Active

Active

Touch probe

Mode 9

<

TP

Offset path

Sequence profile (optional)

Start speed

Profile speed

Lp

Inactive

Inactive

Active

Active

Ln

Active

Active

Active

Active

1

0

1

0