C00159 | cause of quick stop qsp, C00160 | status determining error (16bit), C00159 – Lenze 8400 HighLine User Manual

Page 838: Displays a, C00160, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00159

838

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00159

C00160

Parameter | Name:

C00159 | Cause of quick stop QSP

Data type: UNSIGNED_16

Index: 24416

d

= 5F60

h

Bit coded display of the cause/source of the quick stop
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0

Reserved

Bit 1 CAN control word
Bit 2 MCI control word
Bit 3

Reserved

Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Internal signal
Bit 8

Reserved

Bit 9

Reserved

Bit 10 Operating system
Bit 11

Reserved

Bit 12 MCK
Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00160 | Status determining error (16bit)

Data type: UNSIGNED_16

Index: 24415

d

= 5F5F

h

From version 06.00.00

Display of the short 16-bit error number of the status determining error

Structure of the 16-bit error number (bit coding)

Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C00160/1

Status determining error (16-bit)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising