C01231 | mck: manual jog speeds, C01232 | mck: manual jog accelerations, C01233 | mck: manual jog s-ramp time – Lenze 8400 HighLine User Manual

Page 1073: C01231/1, C01232/1, C01232/2, C01233/1, Active, C01231/2, 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1073

15

Parameter reference

15.2

Parameter list | C01231

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01231

C01232

C01233

Parameter | Name:

C01231 | MCK: Manual jog speeds

Data type: INTEGER_32

Index: 23344

d

= 5B30

h

Manual jog speeds

Manual jog

Setting range

(min. value | unit | max. value)

-214748.3647

units/s

214748.3647

Subcodes

Lenze setting

Info

C01231/1

360.0000 units/s

Manual jog: speed 1

• Regular manual speed

C01231/2

720.0000 units/s

Manual jog: Speed 2

• Second manual speed (can be activated via MCK

control word)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01232 | MCK: Manual jog accelerations

Data type: INTEGER_32

Index: 23343

d

= 5B2F

h

Acceleration/deceleration for manual jog

Manual jog

Setting range

(min. value | unit | max. value)

-214748.3647

units/s2

214748.3647

Subcodes

Lenze setting

Info

C01232/1

720.0000 units/s2

Manual jog: Acceleration

• Acceleration for ramp-up to manual speed.

C01232/2

720.0000 units/s2

Manual jog: Deceleration

• Deceleration for manual speed ramp-down to

standstill.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01233 | MCK: Manual jog S-ramp time

Data type: UNSIGNED_16

Index: 23342

d

= 5B2E

h

S-ramp time for manual jog

• Setting "0 s" ≡ no rounding

Manual jog

Setting range

(min. value | unit | max. value)

0.000

s

10.000

Subcodes

Lenze setting

Info

C01233/1

0.000 s

Manual jog: S-ramp time

• S-ramp time for the manual speed ramps.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Advertising