5motor control (mctrl) – Lenze 8400 HighLine User Manual

Page 145

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

145

5

Motor control (MCTRL)

5.1

Motor selection/Motor data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.1.3

Application notes for asynchronous motors with high slip speed

Examples:

Possible impacts depending on the motor control type:

Remedies:

For version 12.xx.xx and version 13.xx.xx the following applies:

Limit the rated motor speed:

C00087

=

C00089

* 60 / (number of pole pairs + 0.5)

From version 14.00.00:

Set the motor type ("ASM" or "PSM") manually in

C01001/1

. The rated motor speed does not

need to be limited since the number of pole pairs can be detected safely when the motor type

has been set manually.

Note!

If a rated motor speed is set for an asynchronous motor (ASM) in

C00087

which

corresponds to a very high slip speed, the number of motor pole pairs is identified

incorrectly.
Moreover, a synchronous motor is (PSM) is detected instead of an asynchronous motor

(ASM). In this case, the "

Id7

" error message can occur since motor and motor control type

do not match.
Examples, possible impacts and remedies are described in the following sections.

Number of

pole pairs

Mechanical

synchronous speed

Rated motor frequency

(C00089)

Incorrect number of pole pairs if the

rated motor speed (C00087) is lower:

1

3000 rpm

50 Hz

1986 rpm

2

1500 rpm

50 Hz

1195 rpm

3

1000 rpm

50 Hz

854 rpm

4

750 rpm

50 Hz

665 rpm

Motor control type

Possible impacts on the drive

Servo control (SC)

- ASM

The motor can accelerate up to maximum speed of the motor.

V/f control (VFCplus + encoder)
Sensorless vector control (SLVC)

The output speed is considerably too high.

Example: p=2, f

n

=50 Hz, n

n

=1195 min

-1

 Speed is 50 % too high

V/f characteristic control (VFCplus)

Advertising