Motor control (MCTRL)
5.5
V/f characteristic control - energy-saving (VFCplusEco)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.5.2
Comparison of VFCplusEco - VFCplus
The following characteristics show the impact of the energy-saving V/f characteristic control
(VFCplusEco) compared to the standard V/f characteristic control (VFCplus).
• The characteristics were recorded with a standard asynchronous motor 2.2 kW with energy
efficiency class IE1 at speed = 600 rpm.
[5-8]
Comparison of VFCplusEco - VFCplus
scaled torque in [%]
efficiency in [%]
motor voltage in [V]
power factor