2 comparison of vfcpluseco - vfcplus, Comparison of vfcpluseco - vfcplus, 5motor control (mctrl) – Lenze 8400 HighLine User Manual

Page 175

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

175

5

Motor control (MCTRL)

5.5

V/f characteristic control - energy-saving (VFCplusEco)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.5.2

Comparison of VFCplusEco - VFCplus

The following characteristics show the impact of the energy-saving V/f characteristic control

(VFCplusEco) compared to the standard V/f characteristic control (VFCplus).

• The characteristics were recorded with a standard asynchronous motor 2.2 kW with energy

efficiency class IE1 at speed = 600 rpm.

[5-8]

Comparison of VFCplusEco - VFCplus

scaled torque in [%]

efficiency in [%]

motor voltage in [V]

power factor

electrical power in [W]