1339

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tip!
Set the synchronisation window in

C01079/1

higher than the amplitude of beat available

on the input signal:

[17-29] Example: Beat on the input signal

17.1.72.2 Quick stop

The quick stop function removes the drive from the interconnection and leads it to standstill.

• Quick stop is activated by setting bRfg0 to TRUE.

C01076/2

is used to set the delay time in [s] which refers as the acceleration/deceleration time

to the reference speed (

C00011

).

• The angle setpoint created internally on the basis of the input signal nIn_v is saved.
• After bRfg0 is reset to FALSE, the angle setpoint is approached via the ramp function generator

again.

[17-30] Example: Quick stop function (QSP)

nIn_v

t

n

C01077/1

: Maximum speed

C01076/2

: Deceleration time for quick stop

C01076/1

: Acceleration/deceleration time

nOut_v

nIn_v

t

TRUE

FALSE

bRfg0

t

Œ



Ž