17 function library – Lenze 8400 HighLine User Manual

Page 1396

Advertising
background image

17

Function library

17.1

Function blocks

1396

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

nNAct_a

INT

Comparison value for the restart threshold in [%]

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nSet_a

INT

Speed starting point for the deceleration in [%]

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nDCVoltAct_a

INT

Actual DC-bus voltage

• Scaling: 16384 ≡ 1000 V

Identifier

Data type

Value/meaning

nNOut_a

INT

Speed setpoint in [%]

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

bActive

BOOL

Status signal "Mains failure control active"

TRUE The mains failure control is active.

bNCtrlIReset

BOOL

Control signal for resetting the I component of the speed controller in the motor

control

• Connect this output with the bSpeedCtrlIOn input of the

SB

LS_MotionControlKernel

(if this is connected upstream to the motor control).

TRUE Reset I component of the speed controller of the motor control.

Parameter

Possible settings

Info

C01469/1

0.001

31.000 Vp

• Lenze setting: 1.000

C01470/1

1

ms

60000 Vdc-bus controller reset time

• Lenze setting: 20 ms

Note: The set value is internally limited to

20 ... 2000 ms!

If the setting is outside the limits, the limited

value is written back to the code.

C01470/2

1

ms

60000 Acceleration time

• Lenze setting: 20 ms

Note: The set value is internally set to

1 ... 16000 ms!

If the setting is outside the limits, the limited

value is written back to the code.

C01470/3

1

ms

60000 Retrigger time

• Lenze setting: 20 ms

Identifier

Data type

Information/possible settings