17.1.98
L_Limit_2
This FB limits an analog input signal to a value range whose upper and lower limit can be set via
parameters.
Inputs
Outputs
Parameter
Tip!
Always set the lower limit lower than the upper limit, otherwise value "0" is provided at the
nOut_a output.
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
• Scaling: 16384 ≡ 100 %
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
• Scaling: 16384 ≡ 100 %
Parameter
Possible settings
Info
-199.99
%
199.99 Lower limit
• Lenze setting: -100.00 %
-199.99
%
199.99 Upper limit
• Lenze setting: 100.00 %