C00093

C00095

C00097

C00098

C00099

Parameter | Name:

C00093 | Power section identification

Data type: UNSIGNED_16

Index: 24482

d

= 5FA2

h

Display of the identification of the detected power section of the controller
Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00095 | Motor magnetising current

Data type: UNSIGNED_16

Index: 24480

d

= 5FA0

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

320.00 8.50 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00097 | Rated motor torque

Data type: UNSIGNED_32

Index: 24478

d

= 5F9E

h

Display of the rated motor torque

• The value displayed here is calculated from different parameters, e.g. the maximum current set in

C00022

.

Display range

(min. value | unit | max. value)

0.00

Nm

100000.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00098 | Device rated current

Data type: UNSIGNED_16

Index: 24477

d

= 5F9D

h

Display of the rated inverter current which is defined by the integrated power section.
Display range

(min. value | unit | max. value)

0.0

A

6000.0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00099 | Firmware version

Data type: VISIBLE_STRING

Index: 24476

d

= 5F9C

h

Display of the firmware version of the device as string

Read access  Write access  CINH  PLC-STOP  No transfer  COM  MOT

Character length: 12