17 function library – Lenze 8400 HighLine User Manual

Page 1317

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1317

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter

General function

• Every FALSE/TRUE edge at the bClkUp input causes the block to count upwards by "1".
• Every FALSE/TRUE edge at the bClkDown input causes the block to count downwards by "1".

Function "Normal counting"
If the statement of the comparison mode selected in

C01101/1

is true, the bCompare output is set

to TRUE.

Function "Auto reset"
If the statement of the comparison mode selected in

C01101/1

is true, the bCompare output is set

to TRUE for 1 ms and the counter is reset to the wLdVal starting value.

Function "Manual reset"
If the statement of the comparison mode selected in

C01101/1

is true, the bCompare output is set

to TRUE and the counter stops.

• Edges at bClkUp and bClkDown are ignored.
• The counter must be reset via the bLoad input.

Parameter

Possible settings

Info

C01100/1

Function selection

• Lenze setting: Normal counting

0 Normal counting
1 Auto reset
2 Manual reset

C01101/1

Selection of comparison operation

• Lenze setting: Counter

content ≥ comparison value

0 Counter content ≥ comparison value
1 Counter content ≤ comparison value
2 Counter content = comparison value

Advertising