C01251

Bit 9 SpeedNormConstant: Up-Limit

1 ≡ Due to the set machine parameters, an internal

calculation constant is limited to a possible maximum.

Remedy: Reduce reference speed in

C00011

.

Bit 10 Max. speed limit

1 ≡ Due to the set machine parameters, the maximum

speed for specifications in [units/s] are limited to the

factor 150 %.

Bit 11 Quick stop is active

1 ≡ Quick stop function is active.

Bit 12 Quick stop standstill is active

1 ≡ Standstill during active quick stop function (no ramp

generation).

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Bit 16

Reserved

Bit 17

Reserved

Bit 18

Reserved

Bit 19

Reserved

Bit 20

Reserved

Bit 21

Reserved

Bit 22

Reserved

Bit 23

Reserved

Bit 24

Reserved

Bit 25

Reserved

Bit 26

Reserved

Bit 27

Reserved

Bit 28

Reserved

Bit 29

Reserved

Bit 30

Reserved

Bit 31

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01247 | MCK: Diagnostic word

Data type: UNSIGNED_32

Index: 23328

d

= 5B20

h

Parameter | Name:

C01251 | MCK: Acceleration stop

Data type: INTEGER_32

Index: 23324

d

= 5B1C

h

Acceleration parameter for stop

Stop

Setting range

(min. value | unit | max. value)

-214748.3647

units/s2

214748.3647

Subcodes

Lenze setting

Info

C01251/1

720.0000 units/s2

MCK: Stop: Decel.

• Deceleration for setpoint speed ramp-down to

standstill.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000