Function library

17.1

Function blocks

1336

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

bSync

BOOL

Status signal "Drive is running synchronously"

TRUE The drive is running synchronously, the speed input id directly

applied to the speed output.

nOut_v

INT

Speed/angle setpoint

• Scaling: 16384 ≡ 15000 rpm

bFail

BOOL

Status signal "Angular difference exceeded"

TRUE The angular difference set in

C01078/1

has been exceeded.

Parameter

Possible settings

Info

C01076/1

0.000

s

999.900 Acceleration and deceleration time

• Relating to the reference speed

(constant acceleration and

deceleration) set in

C00011

.

• It is a maximum value which

limits the acceleration of the

ramp function generator.

• Lenze setting: 1.000 s

C01076/2

0.000

s

999.900 Deceleration time for quick stop of

the slave drive

• Relating to the reference speed

(constant acceleration and

deceleration) set in

C00011

.

• It is a maximum value which

limits the deceleration of the

ramp function generator.

• Lenze setting: 0.000 s

C01077/1

1

rpm

15000 Max. speed-up

• Lenze setting: 3000 rpm

C01078/1

10

Incr.

2000000000 Following error limit

• Scaling: A revolution is displayed

with 65536 increments or steps.

• Lenze setting: 2000000000 incr.

C01079/1

0

Incr.

65535 Synchronisation window (position)

• If the difference between the

master and the slave is lower than

the synchronisation window, the

bSync status signal is set to TRUE.

• Lenze setting: 100 incr.

C01080/1

-2147483647

Incr.

2147483647 Offset

• Angular offset for the internal

actual position of the FB

• Scaling: A revolution is displayed

with 65536 increments or steps.

• Lenze setting: 0 incr.

Advertising