C02864 | mctrl: optimisiations, T to "1" in, C02864/1 – Lenze 8400 HighLine User Manual

Page 1141: 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1141

15

Parameter reference

15.2

Parameter list | C02864

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02864

Parameter | Name:

C02864 | MCTRL: Optimisiations

Data type: UNSIGNED_16

Index: 21711

d

= 54CF

h

From version 14.00.00

Activation of special functions of the internal motor control
Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Motor temp. 90° for operation

without KTY

1 ≡ Warm machine. In case the temperature tracking is

not active, a motor temperature of 90 °C is assumed.

Bit 1 No switch-off of the brake chopper

after 4s

1 ≡ Limitation of the operating time of the brake chopper

(brake transistor) is deactivated.

Braking operation/brake energy management

Bit 2 Brake chopper off in case of trip

0 ≡ No response of the brake chopper in the "Fault"

device status.

1 ≡ In the "Fault" device status, the brake chopper is

permanently switched off without any delay.

Braking operation/brake energy management

Bit 3 Reserved (do not change!)
Bit 4 Motor ident: Switching frequency

8kHz

Switching frequency for motor parameter identification:

0 ≡ 4 kHz

1 ≡ 8 kHz

Preventing a decrease of the switching frequency

Bit 5 Field/field weakening control in

500us

Cycle time for field weakening control:

0 ≡ 1 ms

1 ≡ 500 μs

Optimising the behaviour of the asynchronous motor

in the field weakening range

Bit 6 Motor ident.: No calculation C577

C578 C2864

From version 15.00.00

: Following successful motor

parameter identification, the field weakening controller

parameters for ASM servo control are calculated as well.

If these parameters are not to be calculated, bit 6 must

be set to "1".

0 ≡ Calculate parameter

1 ≡ Do not calculate parameter

Automatic motor data identification

Bit 7 If C2879 Bit1=0: C087 is warm

From version 15.00.00

, the too high slip with the

activated option "Slip calculation from motor nameplate

data" can be corrected for the ASM servo control by

setting bit 7 to "1".

1 ≡ Rated motor speed (

C00087

) is assumed for a warm

machine.

Slip calculation for SC

Advertising