3.10

PC manual control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.10.2

Speed control

Via the Speed control tab, simply make the drive rotate in the "Speed follower" operating mode

without the need to set control parameters or feedback systems:

How to easily rotate the motor:

1. Set the desired speed setpoint in [%] based on the reference speed, e.g. directly in the

Setpoint PC input field or via the slider.

• Via the -- / 0 / ++ buttons, the currently set speed setpoint can be reduced/increased in

steps of 10 percent or set to zero.

• Via the Set setpoint A/B buttons, the speed setpoint can be set to a previously set

constant value A/B.

2. To start the speed follower:

Enable the controller via the Enable controller button.

• Please observe that the controller will not be enabled if other sources of controller

inhibit (e.g. terminal RFR) are active.

• The enabled drive now follows the defined speed setpoint.
• In order to prevent shocks or overload at higher setpoint changes, the speed setpoint is

lead via a linear ramp generator with adjustable acceleration/deceleration time.

• Via the Inhibit controller button, the controller can be inhibited again, i.e. the motor

becomes torqueless and is coasting unless it already is at standstill.