1505

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

dn2ndPoint_Sizex_p

DINT

Position switch point x: Position of the second switching point or size of the

switching window depending on the CenterMode set in

C01064/x

:

When CenterMode = FALSE:

Position of the second switching point in [increments]

dn2ndPoint_Size_p must be higher than dnSwitchPoint_p.

When CenterMode = TRUE:

Size of the switching window in [increments]

• Due to the symmetrical arrangement of the window around the first switching

point, uneven values are rounded to even values.

• Only positive values are permissible.

Identifier

Data type

Value/meaning

bOut1 ... bOut4

BOOL

Switching output 1 ... 4

TRUE The actual position is inside the defined switching window.

nState

INT

Status

1 FB is not active
2 OK
3 The data form resulting from the switching points are not plausible

(dnSwitchPoint_p, dn2ndPoint_Size_p, parameterised hysteresis).

Parameter

Possible settings

Info

C01062/1...4

0

μs

65535 Dead time for dead time

compensation

• The resulting switching position is

not subject to a plausibility check.

• Lenze setting: 0 μs

C01063/1...4

0

Incr.

65535 Switching hysteresis

• Lenze setting: 0 incr.

C01064/1...4

CenterMode

• Definition how the

dn2ndPoint_Size_p selection is

interpreted.

False dn2ndPoint_Size_p defines the

second switching point.

(Lenze setting)

True dn2ndPoint_Size_p defines the size

of the switching window.

C01065/1...4

0

ms

60000 Running time for position/time-

based cams

• Lenze setting: 0 ms

0 ms = position-based cam

Identifier

Data type

Information/possible settings