159 l_signalswitch32_2, 159 l_signalswitch32_2 7, L_signalswitch32_2 – Lenze 8400 HighLine User Manual

Page 1497: 17 function library

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1497

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.159

L_SignalSwitch32_2

This FB switches between two input signals of the "DINT" data type. The switch-over is controlled by

means of a boolean input signal.

Inputs

Outputs

Identifier

Data type

Information/possible settings

dnIn1

DINT

Input signal 1

dnIn2

DINT

Input signal 2

bSet

BOOL

Selection of the input signal for the output at dnOut

FALSE dnIn1

TRUE dnIn2

Identifier

Data type

Value/meaning

dnOut

DINT

Output signal