Basic drive functions (MCK)

8.12

Holding brake control

614

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Selection of the feedforward control value

From version 06.00.00 onwards

, the feedforward control value can be selected via bit 4 in

C02582

:

• Bit 4 = 0: Automatic selection

• The torque saved at the last stop is used.

• Bit 4 = 1: Manual selection

bMBrakeStartValue2 = FALSE: The feedforward control value 1 set in

C02581/4

is used.

bMBrakeStartValue2 = TRUE: The feedforward control value set in

C02581/5

is used.

Additive torque
If the servo control (SC) operating mode has been selected, an additive torque value in [%] can be

selected via the nBrkTorqueAdd_a input.