_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Selection of the feedforward control value
From version 06.00.00 onwards
, the feedforward control value can be selected via bit 4 in
• Bit 4 = 0: Automatic selection
• The torque saved at the last stop is used.
• Bit 4 = 1: Manual selection
• bMBrakeStartValue2 = FALSE: The feedforward control value 1 set in
is used.
• bMBrakeStartValue2 = TRUE: The feedforward control value set in
is used.
Additive torque
If the servo control (SC) operating mode has been selected, an additive torque value in [%] can be
selected via the nBrkTorqueAdd_a input.
Related topics: