Technology applications

7.6

"GeneralPurpose" functions

486

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.6

"GeneralPurpose" functions

Each technology application provides different free logic and arithmetic functions, so-called

"GeneralPurpose" functions.
For the interconnection of these functions, the application block features inputs and outputs on the

I/O level, which are linked to the logic/arithmetic function.

Tip!
The inputs of the "GeneralPurpose" functions can also be linked to other output signals via

the configuration parameters of the technology application.
On the other hand, the outputs of the "GeneralPurpose" functions can be selected in the

configuration parameters of other inputs.

Related topics:

User-defined terminal assignment

( 361)

TA "Actuating drive speed"

:

Configuration parameters

( 394)

TA "Table positioning"

:

Configuration parameters

( 456)

TA "Switch-off positioning"

:

Configuration parameters

( 483)

7.6.1

Analog switch

This function switches between two analog input signals. The switch-over is controlled by a boolean

input signal.

[7-23] GeneralPurpose function "Analog switch"

• For a detailed functional description see FB

L_AnalogSwitch

.

Note!

In the Lenze setting, the connectors for the "GeneralPurpose" functions are hidden in the

function block editor.

• These connections can be shown via the Connector visibilities command in the

Context menu of the application block.

nGPAnalogSwitchOut_a

nGPAnalogSwitchIn1_a

0

1

nGPAnalogSwitchIn2_a

bGPAnalogSwitchSet

C00830/14

C00830/15

C00833/13