68 l_curve_2, 68 l_curve_2 6, L_curve_2 – Lenze 8400 HighLine User Manual

Page 1326: 17 function library

Advertising
background image

17

Function library

17.1

Function blocks

1326

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.68

L_Curve_2

This FB can optionally display a characteristic function or a curve function y=f(x), the X axis being

the input signal and the Y axis being the output signal.

• A limitation of the input value can be set in

C01026/1

(upper limit) and

C01026/2

(lower limit).

• The output value is internally limited to ±199.99 %. If a limitation of the output value is active,

bLimit is set to TRUE.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

nIn_a

INT

Input value (x)

• ±16384 ≡ ±100 %

• A limitation of the input value can be set in C01026/1 (upper limit) and C01026/2

(lower limit).

Identifier

Data type

Value/meaning

nOut_a

INT

Output value (y)

• ±16384 ≡ ±100 %

• Internal limitation to ±32767 (±199.99 %)

bLimit

BOOL

"Limitation active" status signal

TRUE The output value is limited to ±199.99 %.

Parameter

Possible settings

Info

C00959/2

-199.99

%

199.99 Output value

• Read only

C001025/1

Function selection

0 nOut_a = 0 (FB deactivated)

Lenze setting

1 nOut_a = nIn_a
2 nOut_a = f(x)

In preparation!

3 nOut_a = f(table)

See description of L_Curve_1:

Function 3: nOut_a = f(table)

C01026/1

-199.99

%

199.99 Upper limit for input value

• Lenze setting: 199.99 %

C01026/2

-199.99

%

199.99 Lower limit for input value

• Lenze setting: -199.99 %

/B&XUYHB

Q2XWBD

Q,QBD

E/LPLW

& )XQFWLRQ

[

\

[

\

&

&

&[
&[





&

;9DOB
<9DOB

Advertising