Parameter reference

15.2

Parameter list | C00705

954

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00705

C00706

C00710

C00701/46

0: Not connected

LA_NCtrl

: bFreeIn6

Input for binary user signal 6

C00701/47

0: Not connected

LA_NCtrl

: bFreeIn7

Input for binary user signal 7

C00701/48

0: Not connected

LA_NCtrl

: bFreeIn8

Input for binary user signal 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00701 | LA_NCtrl: Digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Parameter | Name:

C00705 | LA_NCtrl_Out: Analog signal list

Data type: UNSIGNED_16

Index: 23870

d

= 5D3E

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00706 | LA_NCtrl_Out digital signal list

Data type: UNSIGNED_16

Index: 23869

d

= 5D3D

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00710 | LA_TabPos: Analog connection list

Data type: UNSIGNED_16

Index: 23865

d

= 5D39

h

Connection parameters for "Table positioning" application: 16-bit inputs

• Selection of the 16 bit output signals to be connected to the 16 bit input signals

• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the

subcodes.

Selection list
See

selection list - analog signals

Subcodes

Lenze setting

Info

C00710/1

0: Not connected

LA_TabPos

: wCanDriveControl

Input for control word from CAN to device control

C00710/2

0: Not connected

LA_TabPos

: wMciDriveControl

Input for control word from communication interface to

device control

C00710/3

0: Not connected

LA_TabPos

: nTorqueMotLim_a

Input for maximum torque in motor mode

C00710/4

0: Not connected

LA_TabPos

: nTorqueGenLim_a

Input for maximum torque in generator mode

C00710/5

0: Not connected

LA_TabPos

: nMainSetValue_a

Input for main speed setpoint

C00710/6

0: Not connected

LA_TabPos

: nAuxSetValue_a

Input for additional speed setpoint

C00710/7

0: Not connected

LA_TabPos

: wMckCtrl1

Input for MCK control word 1

C00710/8

0: Not connected

LA_TabPos

: wMckCtrl2

Input for MCK control word 2

C00710/9

0: Not connected

LA_TabPos

: wMckOperationMode

Input for selection of MCK operating mode