455

7

Technology applications

7.4

TA "Table positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.4.5

Setting parameters (short overview)

Related topics:

"GeneralPurpose" functions

( 486)

Parameter

Info

Lenze setting

Value Unit

C00012

Accel. time - main setpoint

2.000 s

C00013

Decel. time - main setpoint

2.000 s

C00024

LS_DriveInterface: bNActCompare

0.00 %

C00039/1

Fixed setpoint 1

40.00 %

C00039/2

Fixed setpoint 2

60.00 %

C00182

L_NSet_1: S-ramp time PT1

20.00 s

C00190

L_NSet_1: Setpoint arithmetic

0: Out = Set

C00220

L_NSet_1: Acceleration time - add. setpoint

0.000 s

C00221

L_NSet_1: Deceleration time - add. setpoint

0.000 s

C00632/1

L_NSet_1: Blocking speed 1 max

0.00 %

C00632/2

L_NSet_1: Blocking speed 2 max

0.00 %

C00632/3

L_NSet_1: Blocking speed 3 max

0.00 %

C00633/1

L_NSet_1: Blocking speed 1 min

0.00 %

C00633/2

L_NSet_1: Blocking speed 2 min

0.00 %

C00633/3

L_NSet_1: Blocking speed 3 min

0.00 %

C00635

L_NSet_1: nMaxLimit

199.99 %

C00636

L_NSet_1: nMinLimit

-199.99 %

C00670

L_OffsetGainP_1: Gain

1.0000

C00671

L_OffsetGainP_2: Gain

1.0000

C00696

L_OffsetGainP_1: Offset

0.00 %

C00697

L_OffsetGainP_2: Offset

0.00 %

C00800

L_MPot_1: Upper limit

100.00 %

C00801

L_MPot_1: Lower limit

-100.00 %

C00802

L_MPot_1: Acceleration time

10.0 s

C00803

L_MPot_1: Deceleration time

10.0 s

C00804

L_MPot_1: Inactive fct.

0: Retain value

C00805

L_MPot_1: Init fct.

0: Load last value

C00806

Use of motor potentiometer

0: No

C01297

L_MckStateInterface_1: Alternative function

Bit coded

C01298/1

MCK operating mode at profile no. 0

1: Follower

C01298/2

MCK operating mode at profile no. 1

2: Homing

C01298/3

MCK operating mode at profile no. 2

3: ManualJog

C01298/4

MCK operating mode at profile no. 3...15

4: Positioning

C01299

MCKI: Status MCKInterface

-