Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Homing

1. Request "homing" mode:

Set digital input DI5 to LOW level and digital input DI6 to HIGH level in order to select the

profile 1 and request the "homing" mode at the same time.

2. Start homing:

Set digital input DI7 to HIGH level ("alternative function PosExecute").

3. Complete homing when home position has been reached:

Reset digital input DI7 to LOW level.

Positioning

1. Request "positioning" mode:

Set both digital inputs DI5 and DI6 to HIGH level to select the profile 3 and request the

"positioning" mode at the same time.

2. Start positioning:

Set digital input DI7 to HIGH level ("alternative function PosExecute").

3. Complete positioning if target position has been reached:

Reset digital input DI7 to LOW level.

Tip!
The active operating mode (

C01243

) in the signal flow can also be controlled by means of

the setting of the switch in the "Motion Control Kernel" block.

Related topics:

"Inhibit at power-on" auto-start option

( 122)

Trouble-shooting during commissioning

( 54)

Diagnostics & error management

( 615)