Page 1110: C02250/3, C02250/4, C02251/1, C02251/2, C02251/3, C02251/4, C02252/1

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02250

1110

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02250

C02251

C02252

Parameter | Name:

C02250 | LS_WriteParamList: Filter time - oscill. damping

Data type: UNSIGNED_8

Index: 22325

d

= 5735

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

2

ms

250

Subcodes

Lenze setting

Info

C02250/1

32 ms

LS_WriteParamList

: c235_val1

C02250/2

32 ms

LS_WriteParamList

: c235_val2

C02250/3

32 ms

LS_WriteParamList

: c235_val3

C02250/4

32 ms

LS_WriteParamList

: c235_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02251 | LS_WriteParamList: Oscillation damping field weakening

Data type: UNSIGNED_8

Index: 22324

d

= 5734

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

40

Subcodes

Lenze setting

Info

C02251/1

14

LS_WriteParamList

: c236_val1

C02251/2

14

LS_WriteParamList

: c236_val2

C02251/3

14

LS_WriteParamList

: c236_val3

C02251/4

14

LS_WriteParamList

: c236_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02252 | LS_WriteParamList: Kp position controller

Data type: UNSIGNED_16

Index: 22323

d

= 5733

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

1/s

500.00

Subcodes

Lenze setting

Info

C02252/1

5.00 1/s

LS_WriteParamList

: c254_val1

C02252/2

5.00 1/s

LS_WriteParamList

: c254_val2

C02252/3

5.00 1/s

LS_WriteParamList

: c254_val3

C02252/4

5.00 1/s

LS_WriteParamList

: c254_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100