35 l_convap_3, 35 l_convap_3 3, L_convap_3 – Lenze 8400 HighLine User Manual
Page 1283: 17 function library
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
1283
17
Function library
17.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.35
L_ConvAP_3
This FB converts an analog value into a position.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
nIn_a
INT
Input value
• Scaling: 16384 ≡ 100 %
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2
31
-1 (±2147483647)
Parameter
Possible settings
Info
-32767
32767 Counter
• Lenze setting: 1
-32767
32767 Denominator
• Lenze setting: 1
Note!
Conversion is remainder considered.
/B&RQY$3B
Q,QBD
GQ2XWBS
&
&
dnOut_p
nIn_a C01045/5
C01045/6
-------------------------
⋅
=