61 l_convx_1, 61 l_convx_1 3, L_convx_1 – Lenze 8400 HighLine User Manual

Page 1313: Nnum, Wden, 17 function library

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1313

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.61

L_ConvX_1

This FB scales an analog value.

Inputs

Outputs

Identifier

Data type

Information/possible settings

nIn

INT

Input signal

bInvers

BOOL

Invert sign of the output signal

FALSE

TRUE

nNum

INT

Factor (numerator)

• Internal limitation to -32767 ... -1 / 1 ... 32767

wDenom

WORD

Factor (denominator)

• Internal limitation to 1 ... 32767

Identifier

Data type

Value/meaning

nOut

INT

Output signal

• Internal limitation to ±199 % (100 % ≡ 16384)

Note!

Conversion is remainder considered.

/B&RQY;B

Q,Q

Q2XW

Q1XP

E,QYHUV

Z'HQRP

Q1XP

Z'HQRP

“

“



nOut

nIn

nNum

wDenom

-----------------------

=

nOut

nIn

nNum

wDenom

-----------------------

1

( )

=