8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 573

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

573

8

Basic drive functions (MCK)

8.7

Manual jog

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Manual jog to hardware limit position (limit switch)

[8-32] Example: Manual jog to positive limit switch

Positive limit switch

Deceleration ramp of the quick stop function

• When monitoring of the limit switches

is switched on and a limit switch is

approached during manual jog, the

drive is braked within the deceleration

time set for the quick stop function if

the "TroubleQuickStop" error response

is set in

C00595/1

or

C00595/2

.

n

t

TRUE

FALSE

ManJogPos

t

Œ



Advertising