C01353 | acdrive: setpoint scaling, C01469 | l_mfail: vp, C01470 | l_mfail: tn – Lenze 8400 HighLine User Manual

Page 1092: C01353/1, Ac drive attri, C01353/2, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01353

1092

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01353

C01469

C01470

Parameter | Name:

C01353 | ACDrive: Setpoint scaling

Data type: INTEGER_8

Index: 23222

d

= 5AB6

h

From version 13.00.00

Actuating drive speed (AC Drive Profil): Scaling of the speed and torque values

Setting range

(min. value | unit | max. value)

-128

127

Subcodes

Lenze setting

Info

C01353/1

0

ACDrive: Speed scaling

C01353/2

0

ACDrive: Torque scaling

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01469 | L_MFail: Vp

Data type: UNSIGNED_16

Index: 23106

d

= 5A42

h

Setting range

(min. value | unit | max. value)

0.001

31.000

Subcodes

Lenze setting

Info

C01469/1

1.000

L_MFail_1

: Vp

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01470 | L_MFail: Tn

Data type: UNSIGNED_16

Index: 23105

d

= 5A41

h

Setting range

(min. value | unit | max. value)

1

ms

60000

Subcodes

Lenze setting

Info

C01470/1

20 ms

L_MFail_1

: U DC-bus controller reset time

C01470/2

20 ms

L_MFail_1

: Acceleration time

C01470/3

20 ms

L_MFail_1

: Retrigger time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1