background image

15

Parameter reference

15.2

Parameter list | C00076

818

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00076

C00077

C00078

Parameter | Name:

C00076 | Ti current controller

Data type: UNSIGNED_16

Index: 24499

d

= 5FB3

h

Reset time Ti of the current controller for servo control (

SC

) and certain inverter functions (parameter identification,

flying restart circuit)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

500.00 10.61 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00077 | SC: Vp field controller

Data type: UNSIGNED_16

Index: 24498

d

= 5FB2

h

Gain factor Vp of the field controller for servo control (

SC

)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

500.00 12.80

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00078 | SC: Tn field controller

Data type: UNSIGNED_16

Index: 24497

d

= 5FB1

h

Reset time Tn of the field controller for servo control (

SC

)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

6000.0 256.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10