15 parameter reference – Lenze 8400 HighLine User Manual

Page 803

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

803

15

Parameter reference

15.2

Parameter list | C00007

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

TA "actuating drive speed (AC Drive Profile)"

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Change of direction of

rotation

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Activate manual DC-

injection braking (DCB)

Fixed setpoint 2/3

DI3

Activate manual DC-injection

braking (DCB)

Quick stop

Motor potentiometer:

Increase speed

CW rotation quick stop

DI4

Change of direction of rotation

Motor potentiometer:

Decrease speed

CCW rotation quick stop

A1U, A1I

Local speed/torque setpoint (speed mode: 10 V ≡ 100 % reference speed; torque mode: 10 V ≡ 100 % M

max

)

O1U, O1I

Actual speed value (10 V ≡ 100 % reference speed)

DO1

Status "Drive is ready"

Relay output

Status "Error is pending"

TA "Table positioning"

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable / Reset of error message

DI1

-

-

Positive limit switch

-

DI2

-

-

Negative limit switch

-

DI3

Positive limit switch

-

-

Manual jog

in positive direction

DI4

Negative limit switch

Positioning profile, array bit (valency 4)

Manual jog

in negative direction

DI5

Positioning profile, array bit (valency 2)

DI6

Positioning profile, array bit (valency 1)

DI7

Start of profile generation

A1U, A1I

Main speed setpoint (10 V ≡ 100 % reference speed)

O1U, O1I

Actual speed value (10 V ≡ 100 % reference speed)

O2U, O2I

Current motor current (10 V ≡ 100 % I

max_mot

)

DO1

Status "Drive is ready"

DO2

Status "Target position (actual value) is in the target window"

DO3

Status "Home position is known"

BD1, BD2

Control of the holding brake

Relay output

Status "Error is pending"

"Switch-off positioning" TA

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Stop function 1

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Stop function 2

Selection: Pre-switch off 1

Fixed setpoint 2/3

DI3

Reset error message

CW rotation quick stop

Selection: Switch-off position 1

CW rotation quick stop

DI4

Change of direction of

rotation

CCW rotation quick stop

Selection: Switch-off position 2

CCW rotation quick stop

DI5

-

-

Stop function 2

-

DI6

-

-

Selection: Pre-switch off 2

-

A1U

Main speed setpoint (10 V ≡ 100 % reference speed)

BD1, BD2

Control of the holding brake

Advertising