Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

675

10

Oscilloscope function

10.3

Operation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.3

Operation

This chapter describes step-by-step how to record the signal characteristics of 8400 HighLine

variables and represent, analyse, document and process them in the oscilloscope.

10.3.1

Selecting the variables to be recorded

The oscilloscope supports up to eight channels, i.e. max. eight variables can be recorded in a data

set.
The variables to be recorded can be configured by means of the Vertical channel settings list field.

Four variables have already been selected in the default setting:

Note!

The oscilloscope can only be configured and recording can only be started when an

online connection has been established to the 8400 HighLine.

Column

Name

Meaning

1

-

Curve colour for representation in the oscillogram

2

Ch

Channel number

3

On

On/off

4

Inv

On/off inversion

5

Name

Selection of the variable to be recorded

6

Unit

Scaling

7

1/Div

Vertical scaling factor

8

Offset

Offset value

• The offset value depends on the scaling factor. It is indicated by a dashed

line in the colour of the curve on the left-hand edge of the oscillogram.

9

Position

Position value

• The position value is independent of the scaling factor. It is indicated by a

line on the left-hand edge of the oscillogram.