17

Function library

17.1

Function blocks

1494

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.156

L_SignalSwitch_3

This FB switches between two input signals of the "WORD" data type. The switch-over is controlled

by means of a boolean input signal.

Inputs

Outputs

Identifier

Data type

Information/possible settings

wIn1

WORD

Input signal 1

wIn2

WORD

Input signal 2

bSet

BOOL

Selection of the input signal for the output at wOut

FALSE wIn1

TRUE wIn2

Identifier

Data type

Value/meaning

wOut

WORD

Output signal