C00660 | l_fixset_a_1: analog values, C00661 | l_fixset_w_1: fixed values, C00662 | l_fixset_w_2: fixed values – Lenze 8400 HighLine User Manual

Page 944: C00670 | l_offsetgainp_1: gain, C00670, For a simpl, For a s, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00660

944

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00660

C00661

C00662

C00670

Parameter | Name:

C00660 | L_FixSet_a_1: Analog values

Data type: INTEGER_16

Index: 23915

d

= 5D6B

h

From version 04.00.00

FB

L_FixSet_a_1

: Setting of the fixed values

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00660/1

0.00 %

Fixed value 0 ... 15

C00660/...
C00660/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00661 | L_FixSet_w_1: Fixed values

Data type: UNSIGNED_16

Index: 23914

d

= 5D6A

h

From version 04.00.00

FB

L_FixSet_w_1

: Setting of the fixed values

Setting range

(min. value | unit | max. value)

0

65535

Subcodes

Lenze setting

Info

C00661/1

0

Fixed value 0 ... 15

C00661/...
C00661/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00662 | L_FixSet_w_2: Fixed values

Data type: UNSIGNED_16

Index: 23913

d

= 5D69

h

From version 04.00.00

FB

L_FixSet_w_2

: Setting of the fixed values

Setting range

(min. value | unit | max. value)

0

65535

Subcodes

Lenze setting

Info

C00662/1

0

Fixed value 0 ... 15

C00662/...
C00662/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00670 | L_OffsetGainP_1: Gain

Data type: INTEGER_32

Index: 23905

d

= 5D61

h

The

L_OffsetGainP_1

FB: Gain as multiplier of the input signal + offset

Setting range

(min. value | unit | max. value)

Lenze setting

-100.0000

100.0000 1.0000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Advertising