54 l_convw_4, 54 l_convw_4 6, L_convw_4 – Lenze 8400 HighLine User Manual
Page 1306: 17 function library
17
Function library
17.1
Function blocks
1306
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.54
L_ConvW_4
This FB serves to convert analog signal forms. The following conversions per parameter can be
selected:
• [%] [incr/ms]
• [incr/ms] [%]
• Conversion via parameterisable factors
• Input signal is passed through without conversion
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
wIn
WORD
Input signal
Identifier
Data type
Value/meaning
wOut
WORD
Output signal
Parameter
Possible settings
Info
-32767
32767 Numerator
• Lenze setting: 1
-32767
32767 Denominator
• Lenze setting: 1
Selection of the conversion
0 wOut = wIn (no conversion)
1 [%] [incr/ms]
2 [incr/ms] [%]
3 wOut = wIn *
For conversion formulae see
/B&RQY:B
Z2XW
Z,Q
'HQRPLQDWRU
&RQYHUVLRQ
&
&
&
1XPHUDWRU