69 l_curve_3, 69 l_curve_3 8, L_curve_3 – Lenze 8400 HighLine User Manual

Page 1328: Selec, 17 function library

Advertising
background image

17

Function library

17.1

Function blocks

1328

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.69

L_Curve_3

This FB can optionally display a characteristic function or a curve function y=f(x), the X axis being

the input signal and the Y axis being the output signal.

• A limitation of the input value can be set in

C01031/1

(upper limit) and

C01031/2

(lower limit).

• The output value is internally limited to ±199.99 %. If a limitation of the output value is active,

bLimit is set to TRUE.

Tip!

From version 12.00.00 onwards

the FB L_Curve_3 can be used to create a tensiel force

dependingt on the diameter for winding applications. For this purpose, the FB has been

extended by further inputs/outputs and parameters.

Use of the L_Curve_3 for tensile force characteristic

Inputs

Identifier

Data type

Information/possible settings

nIn_a

INT

Input value (x)

• ±16384 ≡ ±100 %

• A limitation of the input value can be set in C01031/1 (upper limit) and C01031/2

(lower limit).

When using the FB for tensile force characteristic

(from V12.00.00)

:

Maximum tensile force setpoint in [%]

The following inputs are only relevant when the FB is used for tensile force characteristic:
nCurveCtrl_a

INT

From version 12.00.00

Slope of the characteristic (torque characteristic) in [%]

• ±16384 ≡ ±100 %

• Internal limitation to -100 ... +200 %

• With 100 %, there is a constant tensile force curve and thus a torque

proportionally rising with D.

nD0_a

INT

From version 12.00.00

Initial point of the characteristic

• 16384 ≡ 100 % ≡ maximum diameter

nDiameter_a

INT

From version 12.00.00

Current diameter in [%]

• 16384 ≡ 100 % ≡ maximum diameter

bEnableTensionCurve

BOOL

From version 12.00.00

Activate tensile force setpoint

FALSE Tensile force setpoint is not influenced.

TRUE Tensile force setpoint is multiplied by the characteristic value.

/B&XUYHB

Q2XWBD

Q,QBD

E/LPLW

& )XQFWLRQ

[

\

[

\

&

&

&[
&[





&

;9DOB
<9DOB

& 6HOHFWFXUYH

Q&XUYH&WUOBD

Q'BD

Q'LDPHWHUBD

E(QDEOH7HQVLRQ&XUYH

Q&XUYH9DOXHBD

Advertising