3 home position & home value offset, Home position & home value offset, 8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 562

Advertising
background image

8

Basic drive functions (MCK)

8.6

Homing

562

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.6.1.3

Home position & home value offset

If the home position is set in the course of the reference search, this determined position in the

machine measuring system now corresponds to the home position set in

C01227/2

.

If a home value offset has been set in

C01227/1

, the drive continues correctly signed traversing by

this offset at search speed after the home position has been found. The home position is not set

until after this movement.

8.6.1.4

Traversing a sequence profile after completion of homing

If necessary, a sequence (following or subsequent) profile can be entered in

C01228

in order to

arrange for a positioning movement to be carried out immediately after completion of homing.

8.6.1.5

Measurement of the distance between pre-stop mark/limit switch and TP/MP

The measurement is executed for the homing modes 4, 5, 6, 7, 10 and 11.

Note!

The positioning movement for the sequence profile set in

C01228

is also carried out in

the "referencing" mode. If a second sequence (following or subsequent) profile has been

defined in the sequence profile, it is not automatically started!

Jitter of the pre-switch off signal

Depending on how close the pre-stop mark is located to the

encoder zero pulse and even jittering around it, it might occur

that the drive performs one more or one less revolution after

the home position detection has been enabled.

From version 14.00.00

, the display parameter

C01210/9

is

available for this purpose. This parameter shows the distance

between the signal which starts the home position detection

and the detected touch probe signal or encoder zero pulse (MP)

in [units].

Referencing mode

Display in C01210/9 in [units]

4 / 5

dnActPos_p

(TP/MP)

- dnActPos_p

(bHomingMark_TRUE_to_FALSE)

6 / 7

dnActPos_p

(TP/MP)

- dnActPos_p

(bHomingMark_TRUE_to_FALSE)

10

dnActPos_p

(TP/MP)

- dnActPos_p

(bLimitSwitchPos_TRUE_to_FALSE)

11

dnActPos_p

(TP/MP)

- dnActPos_p

(bLimitSwitchNeg_TRUE_to_FALSE)

dnActPos_p

MP

MP

Œ

t