Parameter reference

15.2

Parameter list | C00963

1024

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00963

C00964

C00965

C00966

Parameter | Name:

C00963 | L_Curve_1: Table X-values

Data type: INTEGER_16

Index: 23612

d

= 5C3C

h

From version 04.00.00

FB

L_Curve_1

: X-values for characteristic function

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C00963/1

0

X values 1 ... 32 for characteristic function

C00963/...
C00963/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00964 | L_Curve_1: Table Y-values

Data type: INTEGER_16

Index: 23611

d

= 5C3B

h

From version 04.00.00

FB

L_Curve_1

: Y-value for characteristic function

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C00964/1

0

Y values 1 ... 32 for characteristic function

C00964/...
C00964/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00965 | Max. motor speed

Data type: UNSIGNED_16

Index: 23610

d

= 5C3A

h

From version 10.00.00

When the drive reaches the motor speed set here:

• The "Fault" error response takes place, i.e. the motor is shut down immediately.

• The error message "

oS2: Max. motor speed reached

" is entered into the logbook.

Setting range

(min. value | unit | max. value)

Lenze setting

50

rpm

65000 60000 rpm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00966 | VFC: Time const. slip comp.

Data type: UNSIGNED_16

Index: 23609

d

= 5C39

h

Filter time constant of the slip compensation for V/f characteristic control (

VFCplus

)

• The time constant of slip compensation serves to specify the dynamics of slip compensation for V/f characteristic

control without feedback.

• The lower the selected time constant, the higher the dynamic performance of the slip compensation.

Setting range

(min. value | unit | max. value)

Lenze setting

1

ms

6000 100 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1