C02870 | pli without motion: optimisation factor, C02871 | pli without motion: running time, C02872 – Lenze 8400 HighLine User Manual

Page 1145: C02870, C02871, C02873, After ever, Step by step, G in, An im

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1145

15

Parameter reference

15.2

Parameter list | C02870

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02870

C02871

C02872

C02873

Parameter | Name:

C02870 | PLI without motion: Optimisation factor

Data type: INTEGER_16

Index: 21705

d

= 54C9

h

From version 11.00.00

Pole position identification without motion

Display range

(min. value | unit | max. value)

0.00

%

300.00

Subcodes

Info

C02870/1

PLI without motion: Optimisation factor

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02871 | PLI without motion: Running time

Data type: INTEGER_16

Index: 21704

d

= 54C8

h

From version 11.00.00

Pole position identification without motion

Display range

(min. value | unit | max. value)

0.00

ms

300.00

Subcodes

Info

C02871/1

PLI without motion: Running time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02872 | PLI without motion: Adaptation of time duration

Data type: INTEGER_8

Index: 21703

d

= 54C7

h

From version 11.00.00

Pole position identification without motion

Setting range

(min. value | unit | max. value)

-10

10

Subcodes

Lenze setting

Info

C02872/1

0

PLI without motion: Adaptation of time duration

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02873 | PLI without motion: Ident. el. rotor displ. angle

Data type: INTEGER_16

Index: 21702

d

= 54C6

h

From version 11.00.00

Pole position identification without motion

Display range

(min. value | unit | max. value)

0

°

360

Subcodes

Info

C02873/1

PLI without motion: Ident. el. rotor displ. angle

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising