1 ramp function generator (profile generator), Ramp function generator (profile generator) 7, 17 function library – Lenze 8400 HighLine User Manual

Page 1337

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1337

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.72.1 Ramp function generator (profile generator)

The ramp function generator accelerates the slave drive to the input master speed.

• Synchronising starts when the FB receives a touch probe edge from the master axis (e.g. a

conveying belt) at the bSetTPReceived input.

• When the slave reaches the setpoint speed of the master and the made up path difference is

lower than the synchronisation window set in

C01079/1

, the bSync output is set to TRUE. At the

same time, the FB switches the profile generator to inactive and outputs the nIn_v input speed

to nOut_v.

[17-26] Example: Synchronisation

C01077/1

serves to set a maximum speed which limits the speed of the slave.

C01081/1

Sync. direction/TP function

• Selection of the direction of

rotation for synchronising

• With high offset values and low

input speed, the drive may change

its direction of rotation. In order

to prevent this, a direction of

rotation can be permanently

defined via this parameter.

1 cw/ccw - without TP

(Lenze setting)

2 cw - without TP
3 ccw - without TP
4 cw/ccw - with TP
5 cw - with TP
6 ccw - with TP

Parameter

Possible settings

Info

C01077/1

: Maximum speed

C01076/1

: Acceleration/deceleration time

C01079/1

: Synchronisation window

nOut_v

nIn_v

Ž

TRUE

FALSE

bSync

t

t





Œ

Advertising