C01244 | mck: target detection - times, C01245 | mck: target detection - positions, C01215/1 – Lenze 8400 HighLine User Manual

Page 1080: C01244/3, C01245/3, C01244/1, C01245/1, Time set in, C01244/2, C01244/x

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01244

1080

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01244

C01245

Parameter | Name:

C01244 | MCK: Target detection - times

Data type: UNSIGNED_16

Index: 23331

d

= 5B23

h

From version 02.00.00

Timing for various MCK functions
Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C01244/1

100 ms

MCK: Dwell time - target position

• Time expiring after reaching the setpoint position for

positioning processes and enabling the actual

position detection in the target position window.

Target position monitoring

C01244/2

0 ms

MCK: Waiting time following error 1

From version 11.00.00

Following error monitoring system

C01244/3

0 ms

MCK: Waiting time following error 2

From version 11.00.00

Following error monitoring system

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01245 | MCK: Target detection - positions

Data type: INTEGER_32

Index: 23330

d

= 5B22

h

From version 02.00.00

Position settings for various MCK functions
Setting range

(min. value | unit | max. value)

0.0000

units

214748.3647

Subcodes

Lenze setting

Info

C01245/1

1.0000 units

MCK: Window target position

• Window around the target position for comparison

with the actual position to see whether the drive is in

target.

Target position monitoring

C01245/2

1.0000 units

MCK: Blocking zone Modulo

From version 06.00.00

Activation of the Modulo measuring system

C01245/3

0.0000 units

MCKI: Hysteresis position change

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Advertising