C00155 | extended status word, C00155, 15 parameter reference – Lenze 8400 HighLine User Manual

Page 836

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00155

836

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00155

Parameter | Name:

C00155 | Extended status word

Data type: UNSIGNED_16

Index: 24420

d

= 5F64

h

Bit coded device status word 2
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Fail

Fault

Bit 1 M_max

Maximum torque

Bit 2 I_max

Maximum current

Bit 3 PowerDisabled

Power switched off

Bit 4 Ready

Controller is ready for operation

Bit 5 ControllerInhibit

Controller is inhibited

Bit 6 Trouble

Trouble

Bit 7 InitState

Initialisation

Bit 8 CwCcw

CW/CCW rotation

Bit 9 TroubleQSP

Quick stop due to fault is active

Bit 10 SafeTorqueOff

Safe torque off

Bit 11 AplicationRunning

Application is running

Bit 12 AplParSetBit0

Application parameter set - bit 0

Bit 13 AplParSetBit1

Application parameter set - bit 1

Bit 14 Quick stop

Quick stop active

Bit 15 Motor parameter identification

Motor parameter identification is active

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising