C00114 | diginx: inversion, C00115 | di 1/2 & 6/7: fct, C00115/1 – Lenze 8400 HighLine User Manual

Page 826: If necessary. this param, C00115, T in, C00115/2, D via, Depending on the, Ction in

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00114

826

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00114

C00115

Parameter | Name:

C00114 | DigInX: Inversion

Data type: UNSIGNED_16

Index: 24461

d

= 5F8D

h

The polarity of each digital input of the device can be inverted via this bit field.

Digital input terminals

Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0000 (decimal: 0)

Value is bit-coded: (= bit set)

Info

Bit 0  DI1 inverted

Inversion of digital input 1

Bit 1  DI2 inverted

Inversion of digital input 2

Bit 2  DI3 inverted

Inversion of digital input 3

Bit 3  DI4 inverted

Inversion of digital input 4

Bit 4  DI5 inverted

Inversion of digital input 5

Bit 5  DI6 inverted

Inversion of digital input 6

Bit 6  DI7 inverted

Inversion of digital input 7

Bit 7 

Reserved

Bit 8 

Reserved

Bit 9 

Reserved

Bit 10 

Reserved

Bit 11 

Reserved

Bit 12 

Reserved

Bit 13 

Reserved

Bit 14 

Reserved

Bit 15  CInh inverted

Inversion of digital input RFR (controller enable)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00115 | DI 1/2 & 6/7: Fct.

Data type: UNSIGNED_8

Index: 24460

d

= 5F8C

h

Function assignment of the digital terminals DI1/2 and DI6/7

Digital input terminals

:

Function assignment

Selection list

Info

0 DI1(6)=In / DI2(7)=In

DI1/6 = digital input

DI2/7 = digital input

1 DI1(6)=FreqIn / DI2(7)=In

DI1/6 = 1-track frequency input

DI2/7 = digital input

2 DI1(6)&DI2(7)=FreqIn (2-track)

DI1/6 and DI2/7 = 2-track frequency input

3 DI1(6)=FreqIn / DI2(7)=direction

DI1/6 = 1-track frequency input

DI2/7 = specification of direction

4 DI1(6)=CountIn / DI2(7)=In

DI1/6 = counter input

DI2/7 = digital input

Subcodes

Lenze setting

Info

C00115/1

0: DI1(6)=In / DI2(7)=In

Function assignment of DI1 and DI2

C00115/2

0: DI1(6)=In / DI2(7)=In

Function assignment of DI6 and DI7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising